ARTIKEL

A Procedure for Rational Probe Liquids Selection to Determine Hansen Solubility Parameters

23.03.2024
A Procedure for Rational Probe Liquids Selection to Determine Hansen Solubility Parameters

Structured selection of probe liquids for Hansen parameters - Two-step-strategy: The approach is to first determine the approximate position of the 3D-Hansen sphere using a well-selected set of sample liquids of different polarity and chemical structure. Depending on the result of the first step, a specific selection of probe liquids is then made for the final HSP determination.


Abstract

Hansen Solubility Parameters (HSP), viewed in the context of similarity whenever dispersion is focused, offer valuable insights into the surface characteristics of nanoparticles. However, existing methods for determining HSP via the sedimentation of nanoparticles require multiple probe liquids, resulting in time-consuming, costly experiments with potential health risks. To address this, we developed a two-step strategy that enables a systematic selection of liquids. The key element of the approach is to first identify the rough location of the Hansen sphere in the three-dimensional Hansen space using a well-chosen set of probe liquids of different polarities and chemical structures. Then, depending on the outcome of the first step, a particular choice of liquids is made for the final HSP determination. Taken together, the introduced procedure reduces the amount of required liquids for experiments from currently more than ten to a maximum of seven chosen based on a well-defined, coherent methodology. Validation was performed on carbon black, non-pigmentary nano-scale titania, silicon/carbon composites, and lanthanum cobaltite particles, i. e., relevant materials that are commonly utilized in fuel cells, batteries, cyclohexene oxidation, catalytic combustion, photocatalysis, and heterogeneous Fenton reactions. The study showcases the potential to save time, costs, and efficiently determine HSP values in a comparable manner.

Verwandte Artikel

A Procedure for Rational Probe Liquids Selection to Determine Hansen Solubility Parameters
54. Deutsche Lebensmittelchemietage 2026 in Kaiserslautern
A Procedure for Rational Probe Liquids Selection to Determine Hansen Solubility Parameters
GDCh-Fachgruppe Patentrecht schreibt Innovationspreis 2027 aus
A Procedure for Rational Probe Liquids Selection to Determine Hansen Solubility Parameters
Primo Levi. His legacy still bonds chemistry and conscience.
A Procedure for Rational Probe Liquids Selection to Determine Hansen Solubility Parameters
„Alles Chlor!“: 088 Schaumgeflüster
A Procedure for Rational Probe Liquids Selection to Determine Hansen Solubility Parameters
GDCh ehrt Ullrich Scherf mit Hermann-Staudinger-Preis